Rock wool external insulation system construction points
1. Before construction, a special construction plan for energy conservation and heat preservation of the project shall be prepared according to the design, requirements of this regulation and relevant technical standards, and the construction personnel shall be provided with technical disclosure and professional technical training
2. The construction of the rockwool board external insulation system for energy-saving insulation projects shall be carried out in accordance with the qualified construction drawing design documents and the approved energy-saving insulation special construction scheme for engineering projects.
3. The manufacturer of rock wool board external insulation system should have professional personnel to provide on-site guidance in the construction process, and cooperate with the construction unit and on-site supervision to do a good job in construction quality control.
4. Materials must be accepted in accordance with specifications, quantity and quality requirements before they can be stored, and they should be kept by specially-assigned personnel. Outdoor stacking is strictly prohibited. Curtain wall rock wool board should be stacked overhead moisture-proof.
No | Item | Rock Wool Board/Blanket | ||
1 | Density (kg/m3) | 60 | 80 | 100 |
2 | Thickness (mm) | 50-120 | 50-120 | 40-100 |
3 | Length * width (mm) | 1200*600 | ||
4 | Service temperature(°C) | ≤650 |